ACRYSPORT ARENA GLAS |
| CLICK HERE FOR ORDER FORM | APPLES OR ORANGES? | CLICK HERE FOR PDF BROCHURE | CLICK HERE FOR CLEANING INSTRUCTIONS |
|
ACRYSPORT
ARENA GLAS – ACRYSPORT ARENA GLAS is a TEC-2000 sister product that gives you the strength of TEC-2000 with the slick properties and optical clarity of the ACP NOXTAT OPTEC lens coating. Our ACRYSPORT ARENA GLAS is scratch and abrasion resistant with the broadest range of chemical and solvent resistance available. ACRYSPORT ARENA GLAS is a transparent coating typically applied from 4 to 6 microns thick.
Applications
ACRYSPORT
ARENA GLAS
can be used in almost any sports application where high impact and
maximum durability is a requirement
Impact
tests- Substrate
Impact
Tests- Coating
Room
Temperature Impact
(1 inch steel ball dropped 50 inches onto coated sheet) Result:
No
fracture, chipping or crazing of coating Low
Temperature Impact
(After conditioning at -40°C,
± 1°C
for not less than 4 hours, drop 1 inch steel ball, 50 inches onto front
surface of sheet) Result:
No
fracture, chipping or crazing of coating Typical Product Data:The ACRYSPORT ARENA GLAS process results in no less than the following minimum specifications:
Luminous
Transmittance Type I – (Clear) 85% Minimum Transmittance Type II – (Tinted) 17% to 23% Transmittance
Haze - <2% Maximum Average
Defects – No defects larger than +/- 10% of substrate manufacturers specifications (pits, bubbles, inclusions, embedded foreign matter.
Abrasion
Tests Taber Abrasion Test (with 500 g. load on each wheel @ 1000 cycles. Haze % measured ASTM D 1003-6L.) Result:
3.0-7.0 ∆ Haze
Steel
Wool Test (with #0000 Steel Wool Pad,
1.12” D @ 25psi & 5 cycles.) Result:
1.0 ∆ Haze
Summers Optical Coating
Hardness Test, 2 ½ Pound
Result: <2%
D
Haze Environmental TestsWater
Immersion Test (in tap water @ 65°C.) Result:
500+hours with no cracking or loss of adhesion.
QUV
Exposure Test (on QUV instr. Manuf. By Q
Panel Corp. Cycle = 8 hrs. Uv @ 70°C & 4 hrs cond. Humidity
@50°C.) Result:
400+hours with no cracking or loss of adhesion.
RS Sunlamp Exposure TestResult:
800+ hours with no cracking or loss of adhesion. UV
Light Yellowness Index Test (after 500 hrs. of
QUV.) Result:
Index = 1-4
Haze after Boiling
(Placed in boiling water for no less than 2 hours, then cooled for 1
hour) Results: No
evidence of peeling, <2%
D Haze
Solvent Resistance
Tests
(with saturated cotton balls for 30 min).
Ethylene Glycol Anti-Freeze Diesel Fuel
Heavy Duty Detergent Heavy Duty Brake Fluid Transmission Fluid (Type A) Isopropyl Alcohol Acetone Result: <2%
D
Haze Chemical
Resistance Tests (applied
and allowed to stand for no less than 6 hours) Liquid
Nerve Gas Agent GB Liquid
Nerve Gas Agent HD Result:
<2%
D
Haze
Weight-
Expansion-
|
|||||||||||||||||||||||||||||||||||||||||